Passive Tritium/C-14 Air Samplers

 


Features:

  • Ultra-reliable tritium air sampler
  • Includes mass flow air control for consistent, precise sampling
  • Collects both HT and HTO with cascaded vials to ensure virtually 100% collection efficiency
  • Thermal oxidizer with a temperature indicator to convert HT to HTO, regulated range 455 – 475 °C
  • Standard flow rate sensitivity for 3H: 10-9 µCi/ml (10-9 Ci/m3) for 7-day period at 100 ml/min
  • High flow rate sensitivity for 3H: 10-9 µCi/ml (10-9 Ci/m3) for 24-hour period at 1 L/min

Description:

The Model TASC-HT-HTO is a high-quality and reliable passive tritium in air sampler.  Airborne tritium in the sample stream is continuously collected in vials filled with a liquid collection medium (water or glyocol).  The amount trapped increases linearly with elapsed time.  At regular intervals, the sampling is stopped, the contents removed and assayed using liquid scintillation counting to determine the amount of radioactivity collected.  Knowing the collection flow rate and the results of the scintillation assay, the average sample activity can be calculated for the period of time over which the sample was collected.   Passive samplers, although they do not provide real-time data, provide a low-cost and highly effective method of measuring extremely low levels for ensuring compliance with local regulations.

The TASC-HT-HTO is carefully designed and engineered so that it is easy to use, reliable, and consistent.  It has been in service for over 23 years, and many of the original units are still working to this day which is a testament to its reliability.  The sample holder tubing is made of 304/316 stainless steel which is cut, bent into shape, and brazed directly into sample holder caps which hold the sample collection bottles.  The whole assembly is leak tested, sandblasted for a uniform finish free of burs and oxidation, and finally electroplated for a bright nickel finish.

The TASC-HT-HTO collects both elemental tritium (HT) and tritium oxide (HTO).  First, the sample air is filtered by a high efficiency HEPA filter (99.99% at 0.1 microns) to remove dust and other particulates.  Next, HTO is directly trapped in the first set of vials, while the HT fraction of airborne tritium is trapped in the second set of vials by converting HT into HTO by means of a tube furnace.  Cascaded sets of vials are used to ensure virtually 100% sample collection.

A highly reliable mass flow meter precisely controls the flow rate through the sampler at a consistent value.  On the standard flow version, the mass flow rate is adjusted at the factory to 100 3 scc/min, and is set by a potentiometer on the flow controller circuit board.  The high flow version includes a front panel potentiometer to easily adjust the flow rate from 300 to 1,000 scc/min.

The front panel of the instrument has digital displays for flow rate, elapsed time, tube furnace temperature, as well as a visual indicator for low sample flow.  The high flow version also includes a digital display for totalized flow (flow rate x elapsed time).

Available in two versions:

Standard flow rate: 100 scc/min, with choice of 6x20mL collection vials or 4x60mL collection vials

High flow rate: 300 to 1,000 scc/min, flow rate adjustable via front panel potentiometer, with 4x250mL collection vials, includes totalized flow display

 

Technical Specifications

TRITIUM in AIR SAMPLE COLLECTING SYSTEM
Model TASC-HTO-HT, standard flow version
Sensitivity for 3H10-9 µ Ci/ml (10-9 Ci/m3) for 7 day period at 100 ml/min
Air Flow Rate100±3 ml/minute factory calibrated set point
Flow MeterMass flow meter, 250 ml/minute full scale
Air Flow Indicatorml/min, Digital Display, 3½-digits, 0.1 to 199.9
Air MoverContinuous duty, diaphragm pump
Elapsed Time IndicatorMultifunction timer module, with maximum time setting of 0.1 to 999.9 hours
Thermal OxidizerTube furnace, regulated range: 455° – 475°C (851° – 887°F)
Temperature Indicator°C, Digital Display, 3½-digits, 1 to 1999
Unit CoolingContinuous duty fan; 1 m3/min (30 CFM) free flow
Sample CollectorsTwo manifolds, one for HT and the other for HTO, made from a silver-brazed construction of stainless steel and brass, nickel electroplated.
Choice ofa)Three polyethylene vials on each manifold, 20 ml volume each, total 6 vials
b) Two polyethylene vials on each manifold, 60 ml volume each, total 4 vials
Sample MediumDistilled water or Propylene Glycol
Power Connection10 feet, three wire, grounded cable.
Power Requirements115VAC or 230VAC, 50-60 Hz, 200 Watts
Overall Dimensions356mm (14”) d X 483mm (19”) w X 310mm (12.2”) h
Weight13.6 kgs (30 pounds)
Sample ConnectionsInlet/Exhaust: Hose barb for 5mm (3/16”) I.D. vinyl tubing
CARBON 14 and TRITIUM in AIR SAMPLE COLLECTING SYSTEM
Model TASC-HTO-HT-C14, standard flow version
Tritium CollectionAs above, plus a separate panel for Carbon 14 Collection
Sensitivity for 14 C10-10 µCi/ml (10-10 Ci/m3) for 7 day sample at 100 ml/min
DesiccantUp to 4 drying columns containing indicating Drierite™
Sample Collector15ml polycarbonate tube
Sample MediumSodium Hydroxide, granular form, 20 – 30 mesh
Available from chemical suppliers as Ascarite™
Overall Dimensions135mm (5.3”) d X 483mm (19”) w X 415mm (16.3”) h
Weight9.1 kgs (20 pounds)
ConnectorsHose barbs for 5mm (3/16”) I.D. vinyl tubing
TRITIUM in AIR SAMPLE COLLECTING SYSTEM
TASC-HTO-HT-HF, High Flow Version
Sensitivity for 3H10-9 µCi/ml (10-9 Ci/m3) for 24 hour period at 1.000 Liters/min
Air Flow Rate RangeAdjustable, 0.300 min. to 1.000 max. (±0.01) Liters/minute
Flow MeterMass flow meter, 1.000 Liters/minute full scale
Air Flow IndicatorLiters/min, Digital Display, 3½-digits, 0.001 to 1.999
Air MoverContinuous duty, diaphragm pump
Elapsed Time IndicatorMultifunction timer module, with maximum time setting of
0.1 to 999.9 hours, and programmable reset
Thermal OxidizerTube furnace, regulated range: 455° – 475°C (851° – 887°F)
Temperature Indicator°C, Digital Display, 3½-digits, 1 to 1999
Unit CoolingContinuous duty fan; 1 m3/min (30 CFM) free flow
Sample CollectorsTwo manifolds made from stainless steel
Two glass bottles, 250 ml volume each mount onto
each manifold for HT and HTO, total of four bottles
Sample MediumDistilled water or Propylene Glycol
Power Connection10 feet, three wire, grounded cable.
Power Requirements115VAC or 230VAC, 50-60 Hz, 300 Watts
Overall Dimensions356mm (14”) d X 483mm (19”) w X 310mm (12.2”) h
Note: 125-150mm (5 to 6”) additional height is required under
the enclosure to permit mounting/dismounting of the bottles
Weight15 kgs (33 pounds)
Sample ConnectionsInlet/Exhaust: Hose barb for 5mm (3/16”) I.D. vinyl tubing

Comments

Popular posts from this blog

Starve nuclear weapons to death with a tritium freeze

Proponents of nuclear non-proliferation will be pleased in late 2020 as the 2017 Treaty on the Prohibition of Nuclear Weapons (TPNW) crosses the threshold of 50 ratifications and enters into force. Under this treaty, it will be illegal to hold nuclear weapons, and the parties will have to dismantle any in their possession. The problem with the TPNW approach is that no state that actually possesses nuclear weapons has signed it or is likely to. An alternative to this ‘all-or-nothing’ approach is needed—a freeze on the production of tritium is a different way to manage nuclear disarmament that will gradually bring an end to nuclear weapons. Tritium and its critical role in nuclear weapons  Tritium is a radioactive isotope of hydrogen (hydrogen-3). It is used in the nuclear weapon systems of most of the five nuclear weapon states (NWS)—China, France, the United Kingdom, the United States and Russia—today to ‘boost’ the yield of a fission weapon or fission primary. It is important to n...